t810s-p016c pcb TRCD/TRCDf sub-miniature dimensions: 23 16.1 10.2(lwh) high-sensitivity models available with low power consumption (200 mw) conform to rohs,elv directive 23 16.1 10.2 23 25 10.2 ordering code TRCD l 12vdc s h 1 2 3 4 5 1. relay model ?? 4. s: sealed ? 2. coil power ? nil: vented(flux-tight) l=0.2w, d=0.36w, n=0.45w 5. ?? 3. coil nominal voltage ??? h: form a 3,5,6,9,12,24,48vdc coil data ? at 20 nominal voltage ?? (vdc) 3 5 6 9 12 24 48 coil resistance ?? ( ?10% ) 20 56 80 180 320 1280 5120 rated current ? (ma) 150 90 75 50 37.5 18.7 9.4 max operate voltage ?? (vdc) 2.25 3.75 4.5 6.75 9 18 36 min release voltage ??? (vdc) 0.15 0.25 0.3 0.45 0.6 1.2 2.4 0.45w coil resistance ?? ( ?10% ) 45 125 180 405 720 2880 11520 rated current ? (ma) 66.7 40 33.3 22.2 16.7 8.3 4.2 max operate voltage ?? (vdc) 2.25 3.75 4.5 6.75 9 18 36 min release voltage ??? (vdc) 0.15 0.25 0.3 0.45 0.6 1.2 2.4 0.2w coil resistance ?? ( ?10% ) 25 69 100 225 400 1600 6400 rated current ? (ma) 120 72 60 40 30 15 7.5 max operate voltage ?? (vdc) 2.25 3.75 4.5 6.75 9 18 36 min release voltage ??? (vdc) 0.15 0.25 0.3 0.45 0.6 1.2 2.4 0.36w max applicablevoltage ?? 70 ??? 130% 23 ??? 170% contact data contact form ? 1h contact material silver alloy load resistive load(cos =1) contact ratings ? 16a 250vac (TRCDf only) 10a 250vac/24vdc 15a 125vac 1/2hp 125vac tv-5a @125vac(lamp) minimum load 100ma 5vdc max switching voltage ?? 250vac/125vdc max switching current ? 16a max switching power ? 4000va/480w contact resistance ? 100m max at 6vdc 1a electrical : 100,000 operations(at30o perations/minute) life expectancy mechanical : 10,000,000 operations(at300operations/minute) e173485 u c s 06001015775 r50066938 e l e c t r o n i c s free datasheet http:///
characteristics data ? insulation resistance ?? 100m min at 500vdc dielectric strength between open contacts ? 750vac(for one minute) between contacts and coil ?? 2500vac(for one minute) operate time ? 15ms release time ?? 8ms temperature range ? -40 to+85 operating extremes : 10g shock resistance damage limits ? : 100g vibration resistance 10-55hz, 1.5mm max. switching frequency ?? mechanical:18,000operations/hr electrical:1,800operations/hr humidity ? 20-85% weight approx 10g safety standard ?? ul cul tv cqc approved standards ?? model( ? ) coiling rating ?? safety standard ?? contact rating ?? tv 16a 250vac 10a 250vac 10a 24vdc ul/cul 10a 250vac 15a 125vac 1/2hp 125vac tv-5a @125vac lamp TRCD or TRCDf 3 to 48vdc cqc 16a 250vac 10a 250vac 10a 24vdc engineering data ? rel ease ti m e operate tim e 12 operate ti m e coil power (w ) time(ms) 2 4 6 8 10 30vdc resistive load 125vac resi sti ve l oad 250vac resi stive load 16 14 12 10 8 6 4 2 1 70 50 30 7 5 3 300 500 conti nuous m ax. permi ssi l e vol tage(16a) continuous m ax. permi ssi l e vol tage(10a) 100 10 maximum coil voltage(%) ambbient temperature ( ) switching current (a) endurance (x10000 operation) free datasheet http:///
overall and mounting dimensions ?? outline dimensions TRCD TRCDf wiring diagrams pc board layouts(bottom view) TRCD TRCDf TRCD TRCDf ( bottom view) ( top view) ( bottom view) ????????? free datasheet http:///
|